Network UPS Tools (NUT)
The Network UPS Tools (NUT) integration allows you to monitor and manage a UPS (battery backup) using a NUT
配置
要将 Network UPS Tools (NUT) device 添加到您的 Home Assistant 实例中,请使用此 My 按钮:
Network UPS Tools (NUT) 可以被 Home Assistant 自动发现。如果发现了实例, 它将显示为 已发现。您可以立即进行设置。
手动配置步骤
如果没有自动发现,请不要担心!您可以设置一个 手动集成条目:
-
浏览到您的 Home Assistant 实例。
-
转到
设置 > 设备与服务。 -
在右下角,选择
Add Integration 按钮。 -
从列表中选择 Network UPS Tools (NUT)。
-
按照屏幕上的说明完成设置。
Setting up the integration requires the following information:
Example Resources
Given the following example output from NUT (your variables may differ):
$ upsc ups_name@192.168.11.5
ups.timer.reboot: 0
battery.voltage: 27.0
ups.firmware.aux: L3 -P
ups.mfr: American Power Conversion
battery.runtime.low: 120
ups.delay.shutdown: 20
ups.load: 19
ups.realpower.nominal: 600
battery.charge.warning: 50
battery.charge.low: 10
ups.vendorid: 051d
ups.timer.shutdown: -1
ups.test.result: No test initiated
ups.firmware: 868.L3 -P.D
battery.mfr.ups.serial: 3B1519X19994
ups.productid: 0002
battery.runtime: 2552
battery.voltage.nominal: 24.0
battery.type: PbAc
ups.mfr.ups.status: OL
ups.model: Back-UPS RS1000G
ups.beeper.status: disabled
battery.charge: 100
input.sensitivity: medium
input.transfer.low: 88
input.transfer.high: 147
input.voltage: 121.0
input.voltage.nominal: 120
input.transfer.reason: input voltage out of range
output.current: 1.10
output.frequency: 60.20
output.voltage: 121.50
output.voltage.nominal: 120
Use the values from the left hand column. Support is included for most
values with ups
, battery
, input
and output
prefixes.
UPS Status - human-readable version
An additional virtual sensor type ups.status.display
is available
translating the UPS status value retrieved from ups.status
into a
human-readable version.
Device Actions
A device action is available for each parameterless NUT commandupscmd -l
command followed by the UPS name:
$ upscmd -l my_ups
Instant commands supported on UPS [my_ups]:
beeper.disable - Disable the UPS beeper
beeper.enable - Enable the UPS beeper
test.battery.start.quick - Start a quick battery test
test.battery.stop - Stop the battery test
These commands will be available as device actions in Home Assistant, allowing you to interact with your UPS.
User Credentials and Permissions
To execute device actions through the NUT integration, you must specify user credentials in the configuration. These credentials are stored in the upsd.users
file, part of the NUT server configuration. This file defines the usernames, passwords, and permissions for users accessing the UPS devices.
No actions will be available if no user credentials are specified for a given device.
Ensure the user you specify has the required permissions to execute the desired commands. Here’s an example of a user with command permissions in the upsd.users
file:
[my_user]
password = my_password
actions = SET
instcmds = ALL
In this example, the user my_user
has permission to execute all commands (instcmds = ALL
).
Please note that Home Assistant cannot determine whether a user can access a specific action without executing it. If you attempt to perform an action for which the user does not have permission, an exception will be thrown at runtime.
Remove integration
This integration follows standard integration removal. No extra steps are required.
从Home Assistant中移除集成实例
- 前往 设置 > 设备与服务 并选择集成卡片。
- 从设备列表中,选择要删除的集成实例。
- 在条目旁边,选择三个点
菜单。然后,选择 删除。