Nibe Heat Pump
The Nibe Heat Pump integration allows you to control and monitor Nibe Heat Pumps
Supported devices:
- F1145/F1155
- S1145/S1155
- F1245/F1255
- F1355/F1355
- S2125
- S320/S325
- F370
- F470
- F730
- S735
- F750
- S1255
- SMO40
- SMOS40
- VVM225
- VVM310
- VVM320
- VVM325
- VVM500
配置
要将 Nibe Heat Pump integration 添加到您的 Home Assistant 实例中,请使用此 My 按钮:
手动配置步骤
如果上述 My 按钮不起作用,您也可以手动执行以下步骤:
-
浏览到您的 Home Assistant 实例。
-
转到
设置 > 设备与服务。 -
在右下角,选择
Add Integration 按钮。 -
从列表中选择 Nibe Heat Pump。
-
按照屏幕上的说明完成设置。
Connection Methods
To communicate with the pump there are a few different connection methods available depending on hardware. At the moment the following methods are supported.
UDP Gateway using NibeGw
The heat pump exposes an RS485 interface for communication with extensions. This can be used to speak to the pump by emulating the Nibe MODBUS40 accessory.
Since the pump will go into an error state if the accessory is not responding, dedicated hardware running a gateway software is the preferable choice.
This can be built using a Raspberry Pi with an RS485 hat, an Arduino with RS485 support or an ESP32 with RS485 converters.
ESPHome
An ESPHome base hardware solution also works well, and integrate nicely into Home Assistant.
Arduino
An Arduino-based solution has been tested by OpenHAB community with Arduino uno + RS485 and Ethernet shields. The ProDiNo NetBoards are also supported. A ProDiNo has an Ethernet and RS-485 port on the board.
Raspberry Pi / Linux
A standard Linux application for running the Nibe Gateway software is also available.
Modbus Connection
Home Assistant support connecting to Nibe heat pumps over Modbus over either TCP or RCU like connections. When connecting to the pump inside a Home Assistant, the Modbus connection string must be specified.
TCP/IP
The newer S-series pump exposes a built-in TCP Modbus server that can be used to communicate with the pump. To enable support for this integration, the pump must be connected to your local network and network (5.2 - Network settings) and Modbus (7.5.9 - Modbus TCP/IP) must be enabled. More details on the Modbus support in the pump can be found in Nibe document M12676EN
tcp://[IP OR HOSTNAME]
tcp://[IP OR HOSTNAME]:502
RCU
If your system is equipped with a MODBUS40 accessory, this can be used to control your pump. To connect Home Assistant to the MODBUS40 accessory, a RS485 USB dongle is needed, which can be locally connected to your Home Assistant system, or on a separate computer exposed via ser2net
-
serial://[DEVICE PATH]
for direct local connection -
rfc2217://[IP OR HOSTNAME]:[PORT]
for a ser2nettype proxy
Support for RCU-based communication is currently untested.